PP

<< Click to Display Table of Contents >>

Navigation:  Reference > RCPs >

PP

This has been replaced but is accepted for compatibility.

Use [*ASK] or [*SET] immediately after control stage.

This RCP takes two forms:

PPx=n,

or

PPx=<>,

This RCP enables you to initialise a PP index before the run starts. If <> is used then you will be prompted for a value when the CL script is run (compiled).

In the RCP x must be a valid PP index name (see Indices ) and n may be any value between 0 and 1000000000.

This RCP takes effect at compilation only.